Capture peripheral arterial clot with the Pounce™ Thrombectomy System.
Efficient removal of acute or chronic thrombi or emboliSpeed When It Matters.
Versatility Where It Counts.
Efficient mechanical removal of acute or chronic peripheral arterial thrombi or emboli across a broad 2–10 mm combined vessel diameter range—designed for speed, simplicity, and versatility.
Speed
Versatility
Readily Deployable,
Streamlined Design
Proprietary dual-basket design. Basket offset and dense mesh pattern for clot capture.
7 Fr Sheath
2–10 mm combined vessel diameter range across device sizes
2–10 mm combined vessel diameter range across device sizes
Vessel
Range Working
Length Guidewire
Compatibility Sheath
Compatibility Basket
Diameter Funnel
Diameter
Range Working
Length Guidewire
Compatibility Sheath
Compatibility Basket
Diameter Funnel
Diameter
Vessel
Range 2–4 mm
Range 2–4 mm
Working
Length 150 cm
Length 150 cm
Guidewire
Compatibility .018”
Compatibility .018”
Sheath
Compatibility ≥ 7 Fr
Compatibility ≥ 7 Fr
Basket
Diameter 4 mm
Diameter 4 mm
Funnel
Diameter 7 mm
Diameter 7 mm
Vessel
Range 3.5–6 mm
Range 3.5–6 mm
Working
Length 135 cm
Length 135 cm
Guidewire
Compatibility .035”
Compatibility .035”
Sheath
Compatibility ≥ 7 Fr
Compatibility ≥ 7 Fr
Basket
Diameter 6 mm
Diameter 6 mm
Funnel
Diameter 7 mm
Diameter 7 mm
Vessel
Range 5.5–10 mm
Range 5.5–10 mm
Working
Length 135 cm
Length 135 cm
Guidewire
Compatibility .035”
Compatibility .035”
Sheath
Compatibility ≥ 7 Fr
Compatibility ≥ 7 Fr
Basket
Diameter 10 mm
Diameter 10 mm
Funnel
Diameter 11 mm
Diameter 11 mm
Ready to bring the Pounce™ Thrombectomy System to your practice?
Contact Local RepClinical Evidence
That Matters
The PROWL Registry is a single-arm, retrospective, multicenter U.S. study of the Pounce™ Thrombectomy System for the non-surgical removal of emboli and thrombi in peripheral arterial vasculature.
Findings
Results from a subset of 160 acute and chronic patients with symptomatic infrainguinal vessel limb ischemia treated with the Pounce™ Thrombectomy System.1Registry*
Adjudicated
Follow Up
Speed
2.0
Median Device Passes per Patient24.1 min
Average Pounce System Use TimeEffectiveness
78.8%
No additional clot-removal treatment of the target lesion after useSuccess
91.7%
Procedural success†Safety
No device-related distal embolization††.One (0.6%) device-related adverse event (flow-limiting dissection)
Grab, Go,
Restore Flow
SFA angiography before (A) and after (B) 2 passes of the Pounce™ System, with thromboembolic debris removed after initial pass (C).2