No two patients are alike. The ALTO® System provides a custom seal designed to conform to the needs of specialized anatomies.
Endologix LLC is the legal manufacturer of the company's devices.
Clinical evidence
Durability from All Angles Across All Anatomies, Choose the ALTO System
Long-term data from independent, non-sponsored studies feature Adaptive Sealing Technology and show that the ALTO device delivers what others can only claim: independent, real-world proof that durable outcomes are possible, even in hostile necks.
10-Year Data*
Long-Term Outcome Results of the Ovation Stent Graft2
95.9%freedom from late Type Ia endoleak at 10 years
Long-Term Outcomes of the Ovation Stent Graft System: Single-Center Experience3
Fino et al., 2025 | Journal of Clinical Medicine99 patients | 45.5% hostile neck anatomy
100%freedom from late Type Ia endoleak at 10 years
0%EVAR/AAA-related mortality
* The 10-year clinical outcomes discussed reflect data from the ovation platform and Adaptive Sealing Technology (AST) experience. The ALTO device incorporates the same foundational AST but was introduced more recently and therefore does not have 10 years of device-specific follow-up. Long-term outcome data include patients treated with earlier-generation Ovation™ devices utilizing AST.
5-Year Data
Polymer Ring Sealing Stents for Abdominal Aortic Aneurysms With “Hostile Neck” Feature: A Safe Alternative for Patients “Less Fit” for Open Repair1
Elsayed et al., 2026 | Seminars in Vascular Surgery63 patients | 100% hostile neck anatomy
93.7%freedom from reintervention at 5 years
100%of patients considered on-label ONLY for Endologix Adaptive Sealing Technology
The ALTO System featured in “The Role of Adaptive Sealing Technology in Clinical Practice” article.
50%of AAA patients requiring treatment are not eligible for on-label+ EVAR4–8+Due to specialized anatomies.
Off-label EVAR is mostly due to:
→ Short neck length→ Small access vessel diameter→ Excessive neck angulation
Personalized by design
The ALTO System offers a personalized experience to meet the individual needs of each patient’s anatomy.
The ALTO stent graft’s exclusive technology is optimized for specialized anatomies, including tortuous iliacs and short necks:
7mm neck indication
13F ID delivery system
Highly comformable limbs
Adaptive Sealing Technology
You need an EVAR solution as unique as they are.
Featuring Adaptive Sealing Technology – only on the ALTO abdominal stent graft system.
Made to conform. Built to perform.
The ALTO System's exclusive adaptive sealing technology creates an effective seal around the vessel wall,
conforming to the patient’s anatomy. This technology eliminates chronic radial force in the seal zone** and results in stable neck diameters out to 5 years4,5
Adaptive with sealing ring conforming to irregular surface, creating a patient specific seal.
Separation of fixation and seal allows you to fixate in healthy tissue and seal closest to renals.
Treat infrarenal neck lengths as short as 7mm and <60° juxtarenal angulation without adjunctive devices.
ALTO’s integrated balloon enables time-saving interoperative deployment and optimizes the molding of the sealing ring.
PTFE iliac limbs with helical nitinol architecture provide flexibility and minimal luminal encroachment.
97.2% Freedom from secondary intervention due to graft occlusion at 5 years.^
**Seal zone for the ALTO stent graft is defined as a location 7mm down for the lowest renal. ^The ENCORE analysis pools data on file from ENCORE Data File: April 12, 2018.
Clinical outcomes
Where versatility and durability meet.
The ENCORE*** analysis
A pooled, retrospective analysis of six trials demonstrated favorable clinical outcomes over five years.
99%Freedom from AAA-related mortality
99%Freedom from conversion
99%Freedom from rupture
98%Freedom from reintervention for type IA endoleak
90%Freedom from device-related reintervention
***The Ovation platform product family includes a series of device iterations using adaptive neck sealing technology such as Ovation, Ovation Prime, Ovation iX, and ALTO. The devices included in the studies used in the ENCORE analysis all include adaptive sealing technology. ALTO was not included in the ENCORE data set. ENCORE includes results from real-world patient population. 3% of patients had neck characteristics beyond the FDA-approved anatomic IFU. Safety and effectiveness of Ovation and ALTO when used outside the IFU have not been established. The ENCORE analysis pools data on file from March 20, 2019.
Click Image To Zoom-In
Case examples
Anatomically adaptive, uniquely powerful
Testimonial Case Examples
highlight the clinical utility of the ALTO device including patient demographics, pre-case planning, intra and post-op results.
Dr. Nicolas Mouawad from McLaren Health System
Short Aortic Neck Case
Dr. Luis Gomez from St. Joseph
Regional Medical Center
Severe Infrarenal Neck Angulation Case
Dr. Venkatesh Ramaiah from HonorHealth Scottsdale Shea Medical Center
Severe Infrarenal Neck Angulation Case Review
Dr. Venkatesh Ramaiah from HonorHealth Scottsdale Shea Medical Center
Large AAA with Small Access Vessels Case Review
Dr. Venkatesh Ramaiah from HonorHealth Scottsdale Shea Medical Center
Short and Angulated Neck Case Review
Dr. Robert Beaulieu from the University of Michigan
Large Infra-renal Aortic Aneurysm Case Review
Dr. Luis Gomez Case Review
Experience the ALTO System today: Sign up for VR training demo.
For information on the company's privacy practices, see our Privacy Statement
Rhevera Medical Holdings is the parent company of Endologix LLC. Endologix LLC is the legal manufacturer of the company's devices.
These are a portrayal of typical EVAR patients and not real patients.
REFERENCES
Elsayed Y, Bakheet M, Ahmed N, et al. Polymer ring sealing stents for abdominal aortic aneurysms with “hostile neck” feature: a safe alternative for patients “less fit” for open repair. Annals of Vascular Surgery. 2026;129:437-442. doi:https://doi.org/10.1016/j.avsg.2026.03.039
Debbaut T, Fourneau I, Maleux G, et al. Long-term outcome results of the Ovation stent graft. JVS-Vascular Insights. 2026;4:100439.doi:https://doi.org/10.1016/j.jvsvi.2026.100439
Fino G, Isernia G, Parlani G, et al. Long-term outcomes of the ovation stent graft system: single-center experience. Journal of Clinical Medicine. 2025;14(12):4177. doi:https://doi.org/10.3390/jcm14124177
Barleben A, et al. Long-term outcomes of the Ovation Stent Graft System investigational device exemption trial for endovascular abdominal aortic aneurysm repair. J Vasc Surg. 2020;72(5):1667-1673.
Elkouri S, et al. Most patients with abdominal aortic aneurysm are not suitable for endovascular repair using currently approved bifurcated stent-grafts. Vasc Endovascular Surg. 2004;38:401-12.
Arko FR, et al. How many patients with infrarenal aneurysms are candidates for endovascular repair? The Northern California experience. J Endovasc Ther. 2004;11:33-40.
AbuRahma AF, et al. Aortic neck anatomic features and predictors of outcomes in endovascular repair of abdominal aortic aneurysms following vs not following instructions for use. J Am Coll Surg. 2016;222:579-89.
Schanzer A, et al. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair. Circulation. 2011;123:2848-55.
Legal Information:
Indications and Important Safety Information for Alto Abdominal Stent Graft System
INDICATIONS: The Alto™ Abdominal Stent Graft System is indicated for treatment of patients with infrarenal abdominal aortic aneurysms having the vascular morphology suitable for endovascular repair with the device, which includes the following:
Adequate iliac/femoral access compatible with vascular access techniques (femoral cutdown or percutaneous), devices, and/or accessories,
A proximal aortic landing zone for the sealing ring 7 mm below the inferior renal artery.
An aortic sealing zone comprised of healthy aorta defined as: (1) Lack of significant thrombus > 8 mm in thickness; at any point along the aortic circumference at the level of 7 mm below the inferior renal artery; (2) Lack of significant calcification at the level of 7 mm below the inferior renal artery; (3) Conicity < 10% as measured from the inferior renal artery to the aorta 7 mm below the inferior renal artery, (4) An inner wall diameter of no less than 16 mm and no greater than 30 mm at 7 mm below the inferior renal artery, and (5) An aortic angle of ≤ 60 degrees.
A distal iliac landing zone: with a length of at least 10 mm, and with an inner wall diameter of no less than 8 mm and no greater than 25 mm.
CONTRAINDICATIONS: (1) Patients who have a condition that threatens to infect the graft. (2) Patients with known sensitivities or allergies to the device materials including polytetrafluoroethylene (PTFE), polyethylene glycol (PEG)-based polymers, contrast agents, fluorinated ethylene propylene (FEP), titanium, nickel, platinum, or iridium.
WARNINGS: This device is not recommended in patients who: have or are suspected of having an active systemic infection; cannot tolerate contrast agents necessary for intra-operative and post-operative follow up imaging; and/or have sensitivities or allergies to the stent graft system materials, antiplatelets or anticoagulants; have creatinine level of >2.0mg/dL; have unstable angina and/or myocardial infarction or cerebral vascular accident within 3 months prior to implantation; and/or exceed weight and/or size limits necessary to meet imaging requirements.
PRECAUTIONS: (1) Vessels that are significantly calcified, occlusive, stenotic, tortuous, aneurysmal, or thrombus-lined may preclude placement of the device. (2) Irregular calcification, plaque, and/or thrombus thickness > 8 mm at any point along the aortic circumference of the seal zones may compromise the fixation and/or sealing at the implantation sites.
POSSIBLE ADVERSE EVENTS: Acute and chronic renal failure, renal microembolism, renal insufficiency, renal artery occlusion, contrast toxicity; Amputation; Anesthetic complications and subsequent attendant problems (aspiration); Aneurysm enlargement or rupture; Aortic damage; Aortocaval fistulae; Aortoenteric fistulae; Blood or bleeding; Bowel events; Cardiac events and subsequent attendant problems; Cerebral events (local or systemic) and subsequent attendant problems; Claudication; Contrast toxicity/anaphylaxis; Death; Device events such as deployment or device malfunction, stent fracture, loss of stent graft system component integrity, graft twisting and/or kinking, graft material wear, dilation, erosion, puncture, endograft occlusion, migration, dislodgement; Edema; Embolic and thrombotic events (with transient or permanent ischemia or infarction); Endoleaks (or peri-graft flow); Fever; Gastrointestinal complications; General procedural discomfort; Generalized inflammatory response; Genitourinary complications and subsequent attendant problems; Hematoma (surgical); Hepatic failure; Hypersensitivity (severe allergic reaction and/or anaphylactoid response) to x–ray contrast dye, anti-platelet therapy, device materials including polytetrafluoroethylene (PTFE), polyethylene glycol (PEG)-based polymers, contrast agents, fluorinated ethylene propylene (FEP), titanium, nickel, platinum or iridium; Insertion and other vascular access site complications; Impotence/ sexual dysfunction; Infection; Lymphatic complications and subsequent attendant problems such as lymphocele, lymph fistula; Multi-system organ failure; Neoplasm; Open surgical conversion; Operative and post–operative bleeding and hemorrhage, coagulopathy; Paralysis (temporary or permanent); Pericarditis; Pneumothorax; Polymer leak with hypersensitivity reaction; Prosthesis occlusion/stenosis; Pseudoaneurysm; Pulmonary/respiratory events and subsequent attendant problems; Radiation injury, late malignancy; Sepsis; Seroma; Shock; Spinal neurological deficit; Stenosis/occlusion of native vessel;; Vascular spasm or vascular injury/trauma including damage to blood vessels and surrounding tissues, atherosclerotic ulcer, vessel dissection, perforation, plaque dissection, stenosis, pseudoaneurysm, vessel occlusion, embolization, ischemia, tissue loss, limb loss, gangrenous disease.
CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.
ATTENTION: See Instructions for Use for a complete listing of Indications, Contraindications, Warnings, Precautions, and Adverse Events.
NOTE: Not all product components are available in every country. Please consult with your Rhevera representative to confirm product availability.
Endologix is a registered trademark of Endologix LLC in the United States, Europe and Japan, and Rhevera, Rhevera Medical, the Rhevera logo, ALTO, AFX, Ovation, Detour and Pounce are trademarks of Endologix LLC and its subsidiaries. All other trademarks are the property of their respective owners.